Send Email
Send SMS
Search
Nidhi Meditech Systems
Nidhi Meditech Systems

Home » Products »


Urology Equipment

Our company is regarded as a specialist in offering a huge assortment of Urology Equipment. The wide range of products offered by us includes urology equipment, endoscopic accessories and surgical disposables. These products are made from superior quality stainless steel and other metals and alloys.


Nidhi Flow 814

REQUEST CALLBACK

Nidhi Flow 814
  • Nidhi Flow 814
  • Nidhi Flow 814
  • Nidhi Flow 814
  • Nidhi Flow 814
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

NIDHI-Flow-814 is a fully automatic microprocessor based device with digitally controlled wight based flow transducer. It is designed to monitor the urinary volume and flow rate within a urine collection beaker during micturation. NIDHI-Flow-814 system is quite expedient for very practical day to day flow study.

When the micturation process starts, a volume change is sensed by the microprocessor based device automatically, which determines and stores urinary volume, flow rate and time along with other parameters. At the end of micturation process the microprocessor based device programmed to determine parameters relating to urinary flowlike voided volume, voiding time, flow time, maximum flow rate, average flow rate and time to maximum flow. It also provides the graphical flow curve of the micturation process by the means of flow rate v/s time. At the end of micturation process, by automatic preset delay, it gives a printout which consists of a graphical flow curve as well as statistics relating to parameters of urinary flow altogether with the patients information.


The urinary system consists of two kidneys, two ureters, bladder and urethra. The kidneys principally function to filter the waste products from the blood and circulate the cleaned blood in the body. The ureters carry the waste products (urine) from the kidneys to the bladder. In the bladder, the urine is stored until urination. Thereafter, the urine passes out of the bladder through urethra.

Prostate is a accessory sex gland found in men at the base of the urinary bladder and surrounds the urethra. As the men age, the prostate gland slowly enlarge (called BPH) and may press on the urethra and cause flow of urine to be slower and less forceful with some other adverse symptoms. BPH is diagnosed with the help of ultra sound examination of urinary system and uroflowmetry.

Uroflowmetry is one way of integrating the activity of the bladder and the outlet during the emptying phase of micturation. The micturation process consists of detrusor function of bladder neck opening and urethral conductivity. It can establish the type of abnormality and filter the patients who require further invasive procedures. Thus, it avoids under treatment in the


Additional Information:

  • Item Code: Nidhiflow814
  • Yes! I am Interested

    Urine Flow Meter

    REQUEST CALLBACK

    Urine Flow Meter
    • Urine Flow Meter
    • Urine Flow Meter
    • Urine Flow Meter
    • Urine Flow Meter
    Ask for Price

    Thanks for Contacting Us.

    Product Price :Get Latest Price

    NIDHI-Flow-814 is a fully automatic microprocessor based device with digitally controlled wight based flow transducer. It is designed to monitor the urinary volume and flow rate within a urine collection beaker during micturation. NIDHI-Flow-814 system is quite expedient for very practical day to day flow study.

    When the micturation process starts, a volume change is sensed by the microprocessor based device automatically, which determines and stores urinary volume, flow rate and time alongwith other parameters. At the end of micturation process the microprocessor based device programmed to determine parameters relating to urinary flowlike voided volume, voiding time, flow time, maximum flow rate, average flow rate and time to maximum flow. It also provides the graphical flow curve of the micturation process by the means of flow rate v/s time. At the end of micturation process, by automatic preset delay, it gives a printout which consists of a graphical flow curve as well as statistics relating to parameters of urinary flow altogether with the patients information.


    The urinary system consists of two kidneys, two ureters, bladder and urethra. The kidneys principally function to filter the waste products from the blood and circulate the cleaned blood in the body. The ureters carry the waste products (urine) from the kidneys to the bladder. In the bladder, the urine is stored until urination. Thereafter, the urine passes out of the bladder through urethra.

    Prostate is a accessory sex gland found in men at the base of the urinary bladder and surrounds the urethra. As the men age, the prostate gland slowly enlarge (called BPH) and may press on the urethra and cause flow of urine to be slower and less forceful with some other adverse symptoms. BPH is diagnosed with the help of ultra sound examination of urinary system and uroflowmetry.

    Uroflowmetry is one way of integrating the activity of the bladder and the outlet during the emptying phase of micturation. The micturation process consists of detrusor function of bladder neck opening and urethral conductivity. It can establish the type of abnormality and filter the patients who require further invasive procedures. Thus, it avoids under treatment in the younger age group & restricts overzealous invasive procedure in the older age group.


    Additional Information:

  • Item Code: Flow814
  • Yes! I am Interested

     
    X


    Explore More Products

    Contact via E-mail
    Contact via SMS
    Nidhi Meditech Systems
    Divyang Shah (CEO)
    A-207, Tirthraj Complex, Opposite V. S. Hospital Ellis Bridge, Paldi,
    Ahmedabad - 380006, Gujarat, India
    Call Us: 
    Call Response Rate: 82%
    Share Us :
    F G T L



    Home  |   About Us   |  Products  |  Site Map  |   Contact Us

    © Nidhi Meditech Systems. All Rights Reserved (Terms of Use)
    Developed and Managed by IndiaMART InterMESH Limited

    Nidhi Meditech Systems